Standards and Procedures
Welcome to the central resource hub for Collier County Public Utilities standards and procedures. This page provides contractors, engineers, and developers with the essential documents, forms, and manuals required for water, sewer, and irrigation projects within the county.
Ordinances
Ordinance 2004-31(PDF, 257KB), Utilities Standards and Procedures
Ordinance 2007-60(PDF, 268KB), Amendment to Utilities Standards and Procedures
Ordinance 2018-36(PDF, 13MB), Utilities Standards and Procedures
Ordinance 2021-24(PDF, 8MB), Amendment to Utilities Standards and Procedures
Utilities Standards Manuel
Section 3 - Utilities Detail Drawings(PDF, 10MB)
Details And CAD Files
Access individual files below
General Details
| CAD |
PDF |
Description |
Revision Date |
| CAD - G-1(DWG, 1MB) |
PDF - G-1(PDF, 82KB) |
Unpaved Area Trench Backfill Detail |
04/2006 |
| CAD - G-2(DWG, 593KB) |
PDF - G-2(PDF, 79KB) |
Paved Area Trench Restoration Detail for Private Roads |
07/2018 |
| CAD - G-2A(DWG, 582KB) |
PDF - G-2A(PDF, 87KB) |
State Road, Major County Road, and Numbered County Road Flowable Fill Road/Trench Restoration |
07/2018 |
| CAD - G-2B(DWG, 726KB) |
PDF - G-2B(PDF, 81KB) |
Road and Trench Restoration for Local Roads |
07/2018 |
| CAD - G-3(DWG, 539KB) |
PDF - G-3(PDF, 115KB) |
Pipe Separation Detail |
07/2018 |
| CAD - G-4(DWG, 1MB) |
PDF - G-4(PDF, 114KB) |
Pipe Conflict Detail |
04/2006 |
| CAD - G-5(DWG, 627KB) |
PDF - G-5(PDF, 132KB) |
Jack and Bore Detail |
08/2008 |
| CAD - G-6(DWG, 619KB) |
PDF - G-6(PDF, 87KB) |
Thrust Block Detail for Existing A / C Pipe |
04/2006 |
| CAD - G-7(DWG, 961KB) |
PDF - G-7(PDF, 95KB) |
Typical Valve Setting Detail |
07/2018 |
| CAD - G-8(DWG, 569KB) |
PDF - G-8(PDF, 388KB) |
Typical Horizontal Directional Drill (HDD) Under a Roadway |
07/2018 |
| CAD - G-9(DWG, 569KB) |
PDF - G-9(PDF, 92KB) |
Typical Subaqueous Horizontal Directional Drill (HDD) |
07/2018 |
| CAD - G-9A(DWG, 618KB) |
PDF - G-9A(PDF, 91KB) |
Subaqueous Water Main Valve Detail |
07/2018 |
| CAD - G-10(DWG, 601KB) |
PDF - G-10(PDF, 95KB) |
Pipe Restraint Schedule |
01/2025 |
| CAD - G-11(DWG, 526KB) |
PDF - G-11(PDF, 65KB) |
Vehicular Guard Post Detail |
07/2018 |
| CAD - G-12(DWG, 724KB) |
PDF - G-12(PDF, 195KB) |
IT Fiber-Optic Telecommunications Detail |
01/2025 |
Non-Potable Irrigation Water Details
| CAD |
PDF |
Description |
Revision Date |
| CAD - NP-1(DWG, 684KB) |
PDF - NP-1(PDF, 114KB) |
Standard Irrigation Water Non-Telemetry Meter
Assembly 3" and Larger |
07/2018 |
| CAD - NP-2(DWG, 695KB) |
PDF - NP-2(PDF, 159KB) |
Typical Irrigation Service Meter Setting Detail for Connection To Irrigation Main |
05/2009 |
| NP-3 |
NP-3 |
Not Used |
|
| CAD - NP-4(DWG, 671KB) |
PDF - NP-4(PDF, 93KB) |
Reuse, Raw, and Supplemental Water Air Release Valve Detail |
05/2009 |
| CAD - NP-E1(DWG, 581KB) |
PDF - NP-E1(PDF, 94KB) |
Reuse System Standard Service Connections Open/Close
Valve Single Control Panel Site General Note and Keynotes |
04/2006 |
| CAD - NP-E2(DWG, 1MB) |
PDF - NP-E2(PDF, 163KB) |
Standard Irrigation Water Meter Assembly 3" and Larger - Telemetry |
07/2018 |
| CAD - NP-E3(DWG, 703KB) |
PDF - NP-E3(PDF, 194KB) |
Reuse System Standard Service Connections Open/Close
Valve Single Control Panel Site Layout & Elementary |
08/2008 |
| CAD - NP-E4(DWG, 662KB) |
PDF - NP-E4(PDF, 199KB) |
Reuse System Standard Service Connections Open/Close
Valve Single Control Panel Site Open/Closed MOV
Control Diagram |
04/2006 |
| CAD - NP-E5(DWG, 620KB) |
PDF - NP-E5(PDF, 109KB) |
Reuse System Standard Service Connections Open/Close
Valve Single Control Panel Site Electrical Equipment Elevations |
08/2008 |
| CAD - NP-E6(DWG, 622KB) |
PDF - NP-E6(PDF, 90KB) |
Reuse System Standard Service Connections Open/Close Valve
Single Control Panel Site Level Transducer Mounting Details |
08/2008 |
| CAD - NP-E7(DWG, 658KB) |
PDF - NP-E7(PDF, 130KB) |
Reuse System Standard Service Connections Open/Close Valve Single Control Panel Site Electrical Details |
08/2008 |
| CAD - NP-E8(DWG, 632KB) |
PDF - NP-E8(PDF, 87KB) |
Reuse System Standard Service Connections Open/Close
Valve Single Control Panel Site Electrical Details |
04/2006 |
| CAD - NP-E9(DWG, 669KB) |
PDF - NP-E9(PDF, 139KB) |
Reuse System Standard Service Connections Open/Close
Valve Single Control Panel Site Typical RTU Antenna
Tower Details |
08/2008 |
Water Details
| CAD |
PDF |
Description |
Revision Date |
| CAD - W-1(DWG, 630KB) |
PDF - W-1(PDF, 81KB) |
Temporary Blowoff Assembly with Bacterial Sample Point Detail |
01/2014 |
| CAD - W-2(DWG, 644KB) |
PDF - W-2(PDF, 90KB) |
Automatic Water Main Flushing Device Detail |
01/2014 |
| CAD - W-3(DWG, 621KB) |
PDF - W-3(PDF, 99KB) |
Fire Hydrant Detail |
01/2025 |
| CAD - W-4(DWG, 574KB) |
PDF - W-4(PDF, 126KB) |
Connection to Existing Water Main Detail (Gap Configuration) |
07/2018 |
| CAD - W-5(DWG, 662KB) |
PDF - W-5(PDF, 94KB) |
Potable Water Air Release Valve Detail |
08/2008 |
| CAD - W-6(DWG, 631KB) |
PDF - W-6(PDF, 89KB) |
Permanent Bacterial Sample Point Detail |
01/2025 |
| W-7 |
W-7 |
Not Used |
|
| CAD - W-8(DWG, 635KB) |
PDF - W-8(PDF, 120KB) |
2-1/2" and Smaller Fire System Detector Check Assembly Detail |
07/2018 |
| CAD - W-9(DWG, 766KB) |
PDF - W-9(PDF, 153KB) |
Temporary Backflow Preventer and Fire Protection Meter Tie-In Assembly |
01/2009 |
| CAD - W-9A(DWG, 743KB) |
PDF - W-9A(PDF, 137KB) |
Alternate Temporary Backflow Preventer and Fire Protection Meter Tie-in Assembly |
01/2009 |
| W-10 |
W-10 |
Not Used |
|
| W-10A |
W-10A |
Not Used |
|
| CAD - W-11(DWG, 639KB) |
PDF - W-11(PDF, 145KB) |
3" and Larger Fire System Detector Check Assembly Detail |
07/2018 |
| CAD - W-11A(DWG, 719KB) |
PDF - W-11A(PDF, 141KB) |
4" Through 10" Only Compact Fire System Detector Check Assembly Detail |
07/2011 |
| CAD - W-12(DWG, 670KB) |
PDF - W-12(PDF, 103KB) |
Typical Short and Long Side Water Service Meter Setting Detail
for Connection to Water Main |
01/2025 |
| CAD - W-12A(DWG, 608KB) |
PDF - W-12A(PDF, 104KB) |
Service Connection Sizing Chart and Notes |
01/2025 |
| CAD - W-13(DWG, 717KB) |
PDF - W-13(PDF, 157KB) |
3" and Over Potable Water Meter Assembly Detail |
01/2025 |
| CAD - W-14(DWG, 932KB) |
PDF - W-14(PDF, 161KB) |
4" and Over Potable Water Fire and Domestic Meter Assembly Detail |
01/2025 |
| CAD - W-14A(DWG, 647KB) |
PDF - W-14A(PDF, 102KB) |
Maintenance Driveway for Water Meters 3" and Larger |
07/2018 |
| W-15 |
W-15 |
Not Used |
|
| CAD - W-16(DWG, 843KB) |
PDF - W-16(PDF, 184KB) |
Fire Service Dual Detector Check Assembly Over 10" Fire
Main Detail (Dual 8" Assemblies) |
07/2011 |
Wastewater Details
| CAD |
PDF |
Description |
Revision Date |
| CAD - WW-1(DWG, 612KB) |
PDF - WW-1(PDF, 69KB) |
Force Main Connection to Gravity Sanitary Sewer Detail |
04/2006 |
| CAD - WW-2(DWG, 741KB) |
PDF - WW-2(PDF, 92KB) |
Private Force Main Connection to County Force Main Detail |
07/2018 |
| CAD - WW-3(DWG, 1MB) |
PDF - WW-3(PDF, 131KB) |
Precast Reinforced Concrete Manhole Detail |
01/2025 |
| CAD - WW-4(DWG, 1MB) |
PDF - WW-4(PDF, 130KB) |
Shallow Manhole Detail |
01/2025 |
| CAD - WW-5(DWG, 1MB) |
PDF - WW-5(PDF, 131KB) |
Drop Manhole Detail |
01/2025 |
| CAD - WW-6(DWG, 973KB) |
PDF - WW-6(PDF, 72KB) |
Manhole Ring and Cover Detail |
01/2025 |
| CAD - WW-7(DWG, 1MB) |
PDF - WW-7(PDF, 285KB) |
Pump Station Detail - Profile |
01/2025 |
| CAD - WW-7A(DWG, 1MB) |
PDF - WW-7A(PDF, 300KB) |
Pump Station and Wastewater Details |
01/2015 |
| CAD - WW-7B(DWG, 638KB) |
PDF - WW-7B(PDF, 366KB) |
Pump Station Concrete Details |
01/2015 |
| CAD - WW-7C(DWG, 757KB) |
PDF - WW-7C(PDF, 371KB) |
Pump Station and Wastewater Details |
07/2018 |
| CAD - WW-7D(DWG, 2MB) |
PDF - WW-7D(PDF, 569KB) |
Private Grinder Pump Station Detail |
01/2025 |
| CAD - WW-8(DWG, 982KB) |
PDF - WW-8(PDF, 197KB) |
Pump Station Detail - Plan |
01/2025 |
| CAD - WW-8A(DWG, 1MB) |
PDF - WW-8A(PDF, 234KB) |
Community Pump Station with Generator Detail - Plan |
01/2025 |
| CAD - WW-8B(DWG, 1MB) |
PDF - WW-8B(PDF, 227KB) |
Community Pump Station with Diesel Pump Detail - Plan |
01/2025 |
| CAD - WW-9(DWG, 1MB) |
PDF - WW-9(PDF, 211KB) |
Pump Station Control Panel Detail |
01/2025 |
| CAD - WW-9A(DWG, 1MB) |
PDF - WW-9A(PDF, 155KB) |
Community Pump Station Control Panel Detail - VFD Station with Generator |
01/2025 |
| CAD - WW-9B(DWG, 1MB) |
PDF - WW-9B(PDF, 143KB) |
Community Pump Station Control Panel Detail -Non-VFD Station with Generator |
01/2025 |
| CAD - WW-9C(DWG, 652KB) |
PDF - WW-9C(PDF, 299KB) |
Pump Station Lightning Protection Details |
01/2015 |
| CAD - WW-9D(DWG, 615KB) |
PDF - WW-9D(PDF, 413KB) |
Community Pump Station - Riser Diagram with Generator Backup |
01/2015 |
| CAD - WW-9E(DWG, 631KB) |
PDF - WW-9E(PDF, 446KB) |
Community Pump Station - Riser Diagram with Diesel Backup Pump |
01/2015 |
| CAD - WW-10(DWG, 625KB) |
PDF - WW-10(PDF, 101KB) |
Sewer Connection Details - Property, ROW or Easement Line |
05/2009 |
| CAD - WW-11(DWG, 581KB) |
PDF - WW-11(PDF, 85KB) |
Sewer Clean-out Detail - Paved Areas |
07/2018 |
| CAD - WW-12(DWG, 608KB) |
PDF - WW-12(PDF, 71KB) |
Sewer Clean-out Detail - Non Paved Areas |
01/2014 |
| CAD - WW-13(DWG, 695KB) |
PDF - WW-13(PDF, 323KB) |
Force Main Air Release Valve Detail |
01/2015 |
| WW-14 |
WW-14 |
Not Used |
|
| CAD - WW-15(DWG, 623KB) |
PDF - WW-15(PDF, 110KB) |
Typical Flow Line Channels Detail |
04/2006 |
| CAD - WW-16(DWG, 637KB) |
PDF - WW-16(PDF, 102KB) |
Double Sewer Clean-out Detail |
05/2009 |
| CAD - WW-17(DWG, 650KB) |
PDF - WW-17(PDF, 123KB) |
Telemetry Antenna Mount Detail |
08/2008 |
| CAD - WW-18(DWG, 625KB) |
PDF - WW-18(PDF, 125KB) |
Grease Interceptor |
08/2008 |
| CAD - WW-18A(DWG, 583KB) |
PDF - WW-18A(PDF, 85KB) |
Grease Interceptor Tables |
04/2006 |
Appendices
Appendix A: Utility Deviation Form
Any request for a deviation from established water, wastewater, or IQ water standards or procedures shall be submitted on a Utilities Deviation Form.
Utility Deviation Form(PDF, 123KB) (updated 03/2025)
Please email PDF's of Utilities Deviation Forms to Utility Planning: UtilityPlanning@collier.gov
Appendix B: Water Meter Sizing Form
Water Meter Sizing Form PDF(PDF, 151KB)(PDF, 245KB)(Updated 03/2025)
Water Meter Sizing Form EXCEL MS(XLSX, 98KB) - Excel based automated calculator
Appendix C: Final Waiver of Liens
Final Waiver of Liens(PDF, 51KB) - For conveyance of utilities facilities to the County. (Updated 03/2025)
Appendix D: Utilities Conveyance Checklist
Utilities Conveyance Checklist(PDF, 148KB) (Updated 03/2025)
Appendix E: Vendor Product Approval Application Form
Complete and submit this form to apply to be added to the County Approved Product List, Appendix F.
Vendor Product Approval Application Form(PDF, 144KB) (Updated 07/2018)
Appendix F: County Approved Product List
County Approved Product List(PDF, 494KB) (Updated 03/2025)
Appendix G: Approved Backflow Devices
Approved Backflow Devices(PDF, 92KB) (Updated 03/2025)
Appendix H: Basic User Application & Agreement